Monday 1 March 2021

Revealing the Importance of Manual Changeover Switch

In this era, we cannot imagine a home without a power supply. However, electricity may turn deadly for people who are not accustomed to it. With a manual changeover switch, the homeowner just needs to flip a switch to change the power draw from commercial grid to generator.


How To Hook Up A Manual Changeover Switch?

The steps to hook up a manual changeover switch are as follows



manual changeover switch

-

       Connect the armored cable from the transfer switch back to the electric panel

       Now, connect the ground and the neutral wires from the transfer switch to the correct bus bars present on the main panel

       Identify the first circuit that the generator will power

       Take out the power wire from the existing circuit breaker

Expenses Of Hooking Up A Manual Changeover Switch

A manual changeover switch may take approximately $500 to $900 to install. This amount includes labor charges.

What Is a Three Phase Manual Transfer Switch?

A three-phase manual transfer switch is used to switch between two power supplies. Alternately, it may be used to switch in between loads. Hence, they may also be used as isolation switches. Two most commonly used three-phase manual transfer switches are as follows-

       A compact changeover switch- It is rated 20 Ampere to 125 Ampere.

       A heavy-duty unit- It is rated between 63A to 3150 Amps

Features of Manual Transfer Switch?

The features of a manual transfer switch are as follows-

       Auxiliary Contact Kit-

It is pre-wired with terminal blocks. It is also offered as a standard feature with open execution manual changeover switches.

       Handle

It has a flip-flop operating handle for ratings 250 AMP and above. It enables the users to use the switch with both hands. The handle also allows padlocking in its OFF position. It has three padlocks ranging from 05 to 07. The defeat feature of the handle is available both in the On state and during the restoration of the panel door

       Compact Design

       Clear termination access

       Permission to select the manual and auto mode

       Auxiliary contacts

       Fuse Protection

       Padlocking

       Flexibility in mounting

Conclusion

Product development is an ongoing process. The main motive behind designing a changeover switch is to transfer electricity from a commercial power grid to a local generator. This transfer takes place when no outage occurs.  Thus, when the homeowners or the business owners experience a power failure, they may switch over to the generator just by pressing the manual changeover switch.

 